    And the person who found it isn’t doing a good job either, putting new shingles over old. The old should be removed.

    • Atropos@lemmy.world
      link
      fedilink
      English
      arrow-up
      64
      arrow-down
      5
      ·
      3 months ago

      Eh, going over one layer is fine as long as there are no decking or other structural problems. From what I can see here the older ones are in good enough shape.

      • MotoAsh@lemmy.world
        link
        fedilink
        English
        arrow-up
        7
        arrow-down
        47
        ·
        3 months ago

        Ah yes, inches worth of snow in extra weight is tooootally fine… yep, no downsides to increasing deadwwight at all, nope, nosiree, engineers all agree, dead weight needn’t factor in to calculations at all.

        • BarrelAgedBoredom@lemm.ee
          link
          fedilink
          English
          arrow-up
          42
          arrow-down
          4
          ·
          3 months ago

          I was a roofer for a few years. In Florida, a state with some of (if not the) the most strict roof codes in the country. It’s perfectly ok to layer shingles like that and was common practice for a good while. I’ve torn off houses with 4+ layers of shingles several times and had the decking be just fine underneath them. You have no idea what you’re talking about

          • Zoot@reddthat.com
            link
            fedilink
            English
            arrow-up
            17
            arrow-down
            2
            ·
            3 months ago

            I can imagine he’s used to having snow, and when you’ve got 2feet of snow on your roof extra shingles definitely wouldn’t help.

        • Atropos@lemmy.world
          link
          fedilink
          English
          arrow-up
          23
          arrow-down
          1
          ·
          3 months ago

          As an engineer, we only ever agree on two things:

          1. That’s not enough money
          2. That’s not enough time
        • XeroxCool@lemmy.world
          link
          fedilink
          English
          arrow-up
          18
          arrow-down
          2
          ·
          3 months ago

          The weight-per-unit-area of a shingle is dwarfed by the amount of snow it takes to affect a roof.

          These shingles weight 1.8lbs per square foot when installed (3 packs for 99.9sqft at 62lbs per pack). Call it 2lbs/sqft with nails. Ice (the densest form of “snow” weighs 57lbs per cubic foot. 57 divided by 2 gives us a factor of 28.5 to divide into 1ft (the height of 1 cubic foot) to find that a 1/2" layer of ice weighs more than shingles per square foot. I’m not going to worry about the weight of shingles.

          • BearOfaTime@lemm.ee
            link
            fedilink
            English
            arrow-up
            3
            ·
            3 months ago

            And even where it’s a factor, local code will (slowly) reflect actual capability.

            Ive lived in several states, a few which get snow, even the heavy wet kind. Even there code permits up to 3 layers, depending on how the roof is constructed.

      • jmiller@lemm.ee
        link
        fedilink
        English
        arrow-up
        7
        ·
        3 months ago

        A fiberglass mat core with asphalt around it and grit stuck in the asphalt on the top.

          • jmiller@lemm.ee
            link
            fedilink
            English
            arrow-up
            5
            arrow-down
            1
            ·
            3 months ago

            Tiles are great, I’d love to have a roof last 100 years. But they don’t get as much use here because of issues with ice damning up the bottom edge and pooling water up under the tile, which then freezes and expands and dislodges or damags the tile. That can be overcome, but it’s easier and cheaper to use shingles.

            • Saik0@lemmy.saik0.com
              link
              fedilink
              English
              arrow-up
              2
              ·
              3 months ago

              But they don’t get as much use here

              You should clarify “here” a bit more. In AZ tile roofs are EVERYWHERE.

              We end up replacing the underlayment more often than the actual tiles… unless the specific type of tile is no longer made and too many cracked for whatever reason.